İçeriğe geç

Rigol, Teledyne LeCroy, Owon, Hantek, Micsig ve Tekbox Türkiye yetkili distribütörü

Tüm ürünlerimiz orijinal olup üretici ve ithalatçı firmaların garantisi altındadır

Stokta olmayan ürünler için hemen teklif isteyin

Partner Electronic

Teledyne LeCroy LabMaster 10 Zi-A 65 GHz

İlk değerlendirmeyi siz yazın Ürün kodu: PE-255

65 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input. Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode.

Stokta Stok yok
Fiyat teklif üzerine İstediğiniz adedi bize gönderin, size teklif gönderelim.
Teslimat

Tahmini teslimat: Kargoya verildikten sonra ortalama 3 iş günü

50.000,00 ₺ üzeri ücretsiz kargo · 5 iş günü içinde kargoda

Satıcı Partner Electronic
  • 3D Secure ile güvenli ödeme
  • 14 gün içinde iade
  • 50.000,00 ₺ üzeri ücretsiz kargo

65 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input. Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode.

Teknik özellikler

Analog Bandwidth (Max)65 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (1.85mm Inputs)65 GHz
(≥10 mV/div)
Analog Bandwidth @ 50 Ω (-3 dB) (2.4/2.92mm Inputs)36 GHz
(≥5 mV/div)
Rise Time (10-90%, 50 Ω)6.5 ps
(test limit, flatness mode)
Rise Time (20-80%, 50 Ω)4.9 ps
(flatness mode)
Input ChannelsUp to 40, depending on configuration selected.
Up to 80 @ 36 GHz.
Bandwidth LimitersFor ≤ 36 GHz Mode: 1, 3, 4, 6, 8, 13, 16, 20, 25, 30, 33 GHz.
For > 36 GHz Mode: 50, 60 GHz.
Input Impedance2.92mm Inputs: 50 Ω+/-2%
1.85mm Inputs: 50 Ω+/-2%
Input Coupling2.92 mm Inputs: 50 Ω: DC, GND
1.85 mm Inputs: 50 Ω: DC
Maximum Input Voltage2.92 mm Inputs: ±2 Vmax@<76mV/div, 5.5Vrms@≥76mV/div
1.85 mm Inputs: ±2 Vmax@≤80mV/div
Channel-Channel IsolationDC to 36 GHz: 60 dB (>1000:1)
(For any two 2.92mm input channels, same or different v/div settings, typical)
36 to 65 GHz: 40 dB (>100:1)
(For any two 1.85mm input channels, same or different v/div settings, typical)
Vertical Resolution8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity50 Ω (2.92mm): 5 mV-500mV/div, fully variable (5-9.9 mV/div via zoom)
50 Ω (1.85mm): 10 mV-80mV/div, fully variable. Higher gain settings possible through use of external attenuators.
DC Vertical Gain Accuracy (Gain Component of DC Accuracy)±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V
Offset Range50 Ω (1.85 mm):
±500 mV @ 10-80 mV/div
50 Ω (2.92mm):
±500 mV @ 5-75 mV/div
±4 V @ 76 mV/div -500mV/div
Offset Accuracy50 Ω (2.92mm): 5 mV–500mV/div, fully variable (5-9.9 mV/div via zoom)
50 Ω (1.85mm): 10 mV–80mV/div, fully variable. Higher gain settings possible through use of external attenuators.
DC Vertical Offset Accuracy±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit)
TimebasesInternal timebase with 10 GHz clock frequency common to all input channels. Single, distributed 10 GHz clock for all channels ensures precise synchronization with timing accuracy between all channels identical to that provided within a single, conventional oscilloscope package.
Time/Division RangeFor >36 GHz Mode: 10 ps/div - 320 µs/div (maximum capture time is based on 160 GS/s and installed memory).
For ≤36 GHz Mode: 10 ps/div-256 s/div (maximum capture time is based on minimum sample rate of 200kS/s and installed memory).
Clock Accuracy<0.1 ppm + (aging of 0.05 ppm/yr from last calibration)
Sample Clock Jitterup to 3.2ms Acquired Time Range:
50fsrms (Internal Timebase Reference)
50fsrms (External Timebase Reference)
up to 6.4ms Acquired Time Range:
130fsrms (Internal Timebase Reference)
130fsrms (External Timebase Reference)
Delta Time Measurement Accuracy√2*√((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor√((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) secondsrms (TIE)
Jitter Between Channels<130fsrms
(TIE, typical, measured at maximum bandwidth)
Trigger and Interpolator Jitter<0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware),
Channel-Channel Deskew Range±9 x time/div. setting or 25 ns max. (whichever is larger), each channel
External Timebase Reference (Input)10 MHz or 100MHz; 50 Ω impedance, applied at the rear input of MCM-Zi-A Master Control Module
External Timebase Reference (Output)10 MHz or 100 MHz ; 50 Ω impedance, output at the rear of MCM-Zi-A Master Control Module
Single-Shot Sample Rate/Ch160 GS/s on each channel in >36 GHz Mode.
80 GS/s on each channel in ≤36 GHz Mode.
Maximum Trigger Rate1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time1 µs
Standard Memory (4 Ch / 2 Ch / 1Ch) (Number of Segments)64 M / 64 M / 64 M
(In ≤36 GHz Modes, reference memory specification for 36 GHz LabMasters)
(1000)
Memory Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
S-32 Option:
64M / 64M / 64M
(3,500)
M-64 Option:
128M / 128M / 128M
(7,500)
L-128 Option:
256M / 256M / 256M
(15,000)
VL-256 Option:
512M / 512M / 512M
(15,000)
XL-512 Option:
1024M / 1024M / 1024M
(15,000)
(In ≤36 GHz Modes, reference memory specification for LabMaster 10 Zi-A 36 GHz Systems)
AveragingSummed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)From 8.5 to 11 bits vertical resolution
Envelope (Extrema)Envelope, floor, or roof for up to 1 million sweeps
InterpolationLinear or Sin x/x
ModesNormal, Auto, Single, and Stop
SourcesAny Ch 1-4 (Edge, Window, SMART, Cascade triggers), AUX, internal Fast Edge; or any input channel (Edge trigger only) on additional 10-xxZi-A Acquisition Modules (Channels 5 and higher).
Slope and level unique to each source except line trigger.
Coupling ModeDC, AC, HFRej, LFRej
Pre-trigger Delay0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay0-10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time or EventsFrom 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range±4.1 div from center
Trigger Sensitivity with Edge Trigger (1.85/2.4/2.92mm Inputs)For Ch 1-80 of a LabMaster 10 Zi-A system:
3 div @ < 12 GHz
1.5 div @ < 3 GHz
1.0 div @ < 200 MHz
(for DC coupling, ≥ 10 mV/div, 50 Ω)
External Trigger Sensitivity, (Edge Trigger)For Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module:
2 div @ < 1 GHz,
1.5 div @ < 500 MHz,
1.0 div @ < 200 MHz,
(for DC coupling)
Max. Trigger Frequency, SMART TriggerFor Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module:
2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps)
External Trigger Input RangeFor any LabMaster 10xx-Zi-A Acquisition Module: Aux (±0.4 V)
(Only Ch1-4 Acquisition Module has "active" AUX Input)
TV-Composite VideoNot available
Data RatesOption LM10Zi-6GBIT-80B-8B10B-TD: 600 Mb/s to 6.5 Gb/s, Channel 4 input only
Option LM10Zi-14GBIT-80B-8B10B-TD: 600 Mb/s to 14.1 Gb/s, Channel 4 input only
(Note: Channel 3 input will capture signal for triggering when oscilloscope is in ≥25 GHz mode)
Pattern Length80 bits NRZ, eight 8b/10b symbols
Clock and Data OutputsNo Clock and Data Recovery outputs provided
Measurement Trigger Capability0
TypeOn LabMaster MCM-Zi Master Control Module: Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
ResolutionWXGA; 1280 x 768 pixels.
Number of tracesDisplay a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces.
Grid StylesAuto, Single, Dual, Triple, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Twelve, Sixteen. Up to twenty grids available with some software options.
Waveform RepresentationSample dots joined, or sample dots only
Internal Waveform Memory12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
TypeSupports touch screen integration of user-supplied second display with split-grid capability.
(Note: touch screen driver for second display may not be a Fujitsu driver)
ResolutionDetermined by display chosen by user
Intensity256 Intensity Levels, 1-100% adjustable via front panel control
TypesSelect analog or color-graded
Number of Channelsup to 80 simultaneously
Max Sampling Rate160GS/s
Persistence AgingSelect from 500 ms to Infinity
Waveforms/second (continuous)up to 2500 Waveforms/second
OperationFront panel toggle between WaveStream ON (Analog), ON (Color) and OFF
Analog and Color-Graded PersistenceVariable saturation levels; stores each trace's persistence data in memory
Persistence TypesSelect analog, color, or three-dimensional
Trace SelectionActivate persistence on all or any combination of traces
Persistence AgingSelect from 500 ms to infinity
Sweep Display ModesAll accumulated, or all accumulated with last trace highlighted
TypeOption LSIB-2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module.
Transfer Rateup to 325 MB/s (typical) - Maximum of 4 channels (consult Teledyne LeCroy for >4 channels)
Output ProtocolPCI Express, Gen 1 (4 lanes utilized for data transfer)
Control ProtocolTCP/IP
Command SetVia Windows Automation, or via LeCroy Remote Command Set
Processor Memory32 GB standard. Up to 192 GB optionally available.
Operating SystemMicrosoft Windows® 7 Professional Edition (64-bit)
Real Time ClockDate and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
Zoom Expansion TracesDisplay up to 12 Zoom and 12 Math/Zoom traces
Front Panel and Instrument StatusStore to the internal hard drive, over the network, or to a USB-connected peripheral device.
Remote ControlVia Windows Automation, or via LeCroy Remote Command Set
Network Communication StandardVXI-11 or VICP, LXI Class C (v1.2) Compliant
GPIB PortSupports IEEE - 488.2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module.
LSIB Port (optional)Supports PCIe Gen1 x4 protocol with LeCroy supplied API. Installs in LabMaster LabMaster MCM-Zi-A Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi-A Acquisition Module.
Ethernet PortSupports 10/100/1000BaseT Ethernet interface (RJ45 port)
USB PortsLabMaster MCM-Zi -A Master Control Module: minimum 2 total USB 2.0 ports on rear of unit to support Windows compatible devices
LabMaster MCM-Zi -A Master Control Module: minimum 3 total USB 2.0 ports on front of unit to support Windows compatible devices
External Monitor PortDual Link DVI compatible to support internal display on MCM-Zi Master Control Module (1280 x 768 pixel resolution) and customer-supplied monitor with up to WQXGA (2560 x 1600 pixel) resolution using extended desktop mode.
Signal TypesFor External Trigger Input. Located on every LabMaster 10-xxZi-A Acquisition Module (front-mounted BNC, 50 Ω). 10-xxZi-A Acquisition Module that is used for Channels 1-4 contains "active" AUX Input.
Coupling50 Ω: DC
Max. Input Voltage5 Vrms
Signal TypesSelect from calibrator, control signals or Off
Output Signal500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ)
Control SignalsTrigger enabled, trigger out, pass/fail status, off
Connector TypeBNC, located on front of every LabMaster 10-xxZi Acquisition Module. 10-xxZi Acquisition Module that is used for Channels 1-4 contains "active" AUX Output.
Auto SetupAutomatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical ScaleAutomatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
Auto CalibrationEnsures specified DC and timing accuracy is maintained for 1 year minimum.
ProbesNo passive probes supplied
Probe SystemUp to 36 GHz Inputs: 2.92mm interface.
Up to 65 GHz Inputs: 1.85mm interface
2.92mm interface automatically detects and supports a variety of compatible probes.
Use L2.92A-PLINK or L2.92A-PBUS 2.92mm Probe Adapters to connect 50Ω ProLink or ProBus compatible probes to 2.92mm interface.
Scale FactorsAutomatically or manually selected depending on probe used
Calibration OutputMCM-Zi-A Master Control Module: Fast Edge output, 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled
VoltageLabMaster 10-xxZi Acquisition Module: 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II
LabMaster MCM-Zi Master Control Module: 100-240 VAC ±10% at 45-66 Hz; Automatic AC Voltage Selection, Installation Category II
Max. Power ConsumptionLabMaster 10-xxZi-A Acquisition Module - 1275 W / 1275 VA.
LabMaster MCM-Zi-A Master Control Module - 450 W / 450 VA.
Each Module and the CPU has a separate power cord.
Temperature (Operating)+5 °C to +40 °C
Temperature (Non-Operating)-20 °C to +60 °C
Humidity (Operating)5% to 80% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating)5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating)2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
Dimensions (HWD)LabMaster MCM-Zi-A Master Control Module - 10.9"H x 18.2"W x 15.6"D (277 x 462 x 396 mm),
LabMaster 10-xxZi-A Acquisition Module - 8.0"H x 18.2"W x 26"D (202 x 462 x 660 mm)
WeightLabMaster 10-xxZi-A Acquisition Module -58 lbs. (26.4 kg)
LabMaster MCM-Zi-A Master Control Module - 47 lbs. (21.4 kg)
Shipping WeightLabMaster 10-xxZi-A Acquisition Module -76 lbs. (34.5 kg)
LabMaster MCM-Zi-A Master Control Module - 56 lbs. (25.5 kg)
CertificationsCE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, EN61010-2-030, UL 61010-1 3rd edition, and CSA C22.2 No. 61010-1-12
Warranty and Service3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
Bant genişliği
65 GHz
Örnekleme hızı
160 GSa/s
Bellek derinliği
64 Mpts
Dijital kanal
0
  • Teledyne LeCroy WaveScan · YouTube

  • Teledyne LeCroy I2C [French] · YouTube

  • Teledyne LeCroy WaveStream Video Signal · YouTube

  • Teledyne LeCroy LabNotebook · YouTube

  • Teledyne LeCroy EyeDoctor · YouTube

  • Teledyne LeCroy XDEV Customization · YouTube

  • Teledyne LeCroy SDA 8 Zi Oscilloscope · YouTube

  • Teledyne LeCroy WaveScan Measurement [French] · YouTube

  • Teledyne LeCroy SPI [French] · YouTube

  • Teledyne LeCroy WaveStream - Runt Signal · YouTube

Bu ürünü henüz kimse değerlendirmedi.

Yorum yaz

Henüz değerlendirme yok

Ürünü satın alın ve düşüncenizi başkalarıyla paylaşın.

Henüz soru yok

Bu ürün hakkında ilk soruyu siz sorun; cevabı burada gösterilir.

Satıcıya sor

Sorunuz, cevapladığımızda burada gösterilir. Lütfen kişisel bilgi paylaşmayın.

Soru sormak için giriş yapın

Kargo

50.000,00 ₺ ve üzeri siparişlerde kargo bedava. Siparişler 5 iş günü içinde kargoya verilir. Sürat Kargo ile gönderim yapılır.

İadeler

Ürünü teslim aldığınız tarihten itibaren 14 gün içinde, ambalajı ve aksesuarları eksiksiz olmak koşuluyla iade edebilirsiniz. İade talebini Hesabım > Siparişlerim altından oluşturun.

Değişim

Başka bir modelle değişim, iade ve ardından yeni bir sipariş olarak işlenir. İade koşullarını okuyun