0,00 TL (KDV Dahil)
100 GHz, 240 GS/s, 96 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input. Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode. or, 65 GHz, 160 GS/s, 1ch, 64 Mpts/Ch w/ 2 ch at 36 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (1mm Inputs) | 100 GHz (≥10 mV/div) |
Analog Bandwidth (Max) | 65 GHz |
Analog Bandwidth @ 50 Ω (-3 dB) (2.4/2.92mm Inputs) | 36 GHz (≥5 mV/div) |
Rise Time (10-90%, 50 Ω) | 4.5 ps (flatness mode) |
Rise Time (20-80%, 50 Ω) | 3.5 ps (flatness mode) |
Input Channels | Up to 20, depending on configuration selected. Up to 80 @ 36 GHz. |
Bandwidth Limiters | For ≤ 36 GHz Mode: 1, 3, 4, 6, 8, 13, 16, 20, 25, 30, 33 GHz. For 65 GHz Mode: 50, 60 GHz. |
Input Impedance | 2.92mm Inputs: 50 Ω+/-2% 1.mm Inputs: 50 Ω+/-2% |
Input Coupling | 2.92 mm Inputs: 50 Ω: DC, GND 1 mm Inputs: 50 Ω: DC |
Maximum Input Voltage | 2.92 mm Inputs: ±2 Vmax@<76mV/div, 5.5Vrms@≥76mV/div 1 mm Inputs: ±1 Vmax@≤80mV/div |
Channel-Channel Isolation | DC to 36 GHz: 60 dB (>1000:1) (For any two 2.92mm input channels, same or different v/div settings, typical) 65 GHz and 100 GHz mode: N/A |
Vertical Resolution | 8 bits; up to 11 bits with enhanced resolution (ERES) |
Sensitivity | 50 Ω (2.92mm): 5 mV-500mV/div, fully variable (5-9.9 mV/div via zoom) 50 Ω (1mm): 10 mV-80mV/div, fully variable. |
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) | ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V |
Offset Range | 50 Ω (1.mm): ±500 mV @ 10-80 mV/div 50 Ω (2.92mm): ±500 mV @ 5-75 mV/div ±4 V @ 76 mV/div -500mV/div |
Offset Accuracy | 50 Ω (2.92mm): 5 mV–500mV/div, fully variable (5-9.9 mV/div via zoom) 50 Ω (1mm): 10 mV–80mV/div, fully variable. |
DC Vertical Offset Accuracy | ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit) |
Timebases | Internal timebase with 10 GHz clock frequency common to all input channels. Single, distributed 10 GHz clock for all channels ensures precise synchronization with timing accuracy between all channels identical to that provided within a single, conventional oscilloscope package. |
Time/Division Range | For >36 GHz Mode: 10 ps/div - 320 µs/div (maximum capture time is based on 160 GS/s and installed memory). For ≤36 GHz Mode: 10 ps/div-256 s/div (maximum capture time is based on minimum sample rate of 200kS/s and installed memory). |
Clock Accuracy | <0.1 ppm + (aging of 0.05 ppm/yr from last calibration) |
Sample Clock Jitter | up to 3.2ms Acquired Time Range: 50fsrms (Internal Timebase Reference) 50fsrms (External Timebase Reference) up to 6.4ms Acquired Time Range: 130fsrms (Internal Timebase Reference) 130fsrms (External Timebase Reference) |
Delta Time Measurement Accuracy | √2*√((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) (RMS)+(clock accuracy*reading)(seconds) |
Jitter Measurement Floor | √((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) secondsrms (TIE) |
Jitter Between Channels | <130fsrms (TIE, typical, measured at maximum bandwidth) |
Trigger and Interpolator Jitter | <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware), |
Channel-Channel Deskew Range | ±9 x time/div. setting or 25 ns max. (whichever is larger), each channel |
External Timebase Reference (Input) | 10 MHz or 100MHz; 50 Ω impedance, applied at the rear input of MCM-Zi-A Master Control Module |
External Timebase Reference (Output) | 10 MHz or 100 MHz ; 50 Ω impedance, output at the rear of MCM-Zi-A Master Control Module |
Single-Shot Sample Rate/Ch | 240 GS/s on each channel in 100 GHz Mode. 160 GS/s on each channel in 65 GHz Mode. 80 GS/s on each channel in ≤36 GHz Mode. |
Maximum Trigger Rate | 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) |
Intersegment Time | 1 µs |
Standard Memory (4 Ch / 2 Ch / 1Ch) (Number of Segments) | 96 M / 96 M / 96 M (In ≤36 GHz Modes, reference memory specification for 36 GHz LabMasters) (1000) |
Memory Options (4 Ch / 2 Ch / 1Ch) (Number of Segments) |
S-32 Option: 96M / 96M / 96M (3,500) M-64 Option: 192M / 192M / 192M (7,500) L-128 Option: 384M / 384M / 385M (15,000) VL-256 Option: 768M / 768M / 768M (15,000) XL-512 Option: 1536M / 1536M / 1536M (15,000) (In ≤36 GHz Modes, reference memory specification for LabMaster 10 Zi-A 36 GHz Systems) |
Averaging | Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps |
Enhanced Resolution (ERES) | From 8.5 to 11 bits vertical resolution |
Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps |
Interpolation | Linear or Sin x/x |
Modes | Normal, Auto, Single, and Stop |
Sources | Any Ch 1-4 (Edge, Window, SMART, Cascade triggers), AUX, internal Fast Edge; or any input channel (Edge trigger only) on additional 10-xxZi-A Acquisition Modules (Channels 5 and higher). Slope and level unique to each source except line trigger. |
Coupling Mode | DC, AC, HFRej, LFRej |
Pre-trigger Delay | 0-100% of memory size (adjustable in 1% increments of 100 ns) |
Post-trigger Delay | 0-10,000 divisions in real time mode, limited at slower time/div settings or in roll mode |
Hold-off by Time or Events | From 2 ns up to 20 s or from 1 to 99,999,999 events |
Internal Trigger Range | ±4.1 div from center |
Trigger Sensitivity with Edge Trigger (1.85/2.4/2.92mm Inputs) | For Ch 1-80 of a LabMaster 10 Zi-A system: 3 div @ < 12 GHz 1.5 div @ < 3 GHz 1.0 div @ < 200 MHz (for DC coupling, ≥ 10 mV/div, 50 Ω) |
External Trigger Sensitivity, (Edge Trigger) | For Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module: 2 div @ < 1 GHz, 1.5 div @ < 500 MHz, 1.0 div @ < 200 MHz, (for DC coupling) |
Max. Trigger Frequency, SMART Trigger | For Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module: 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps) |
External Trigger Input Range | For any LabMaster 10xx-Zi-A Acquisition Module: Aux (±0.4 V) (Only Ch1-4 Acquisition Module has "active" AUX Input) |
Clock and Data Outputs | No Clock and Data Recovery outputs provided |
Measurement Trigger Capability | 0 |
Type | On LabMaster MCM-Zi Master Control Module: Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen |
Resolution | WXGA; 1280 x 768 pixels. |
Number of traces | Display a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces. |
Grid Styles | Auto, Single, Dual, Triple, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Twelve, Sixteen. Up to twenty grids available with some software options. |
Waveform Representation | Sample dots joined, or sample dots only |
Internal Waveform Memory | 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity. |
Type | Supports touch screen integration of user-supplied second display with split-grid capability. (Note: touch screen driver for second display may not be a Fujitsu driver) |
Resolution | Determined by display chosen by user |
Intensity | 256 Intensity Levels, 1-100% adjustable via front panel control |
Types | Select analog or color-graded |
Number of Channels | up to 80 simultaneously |
Max Sampling Rate | 240 GS/s |
Persistence Aging | Select from 500 ms to Infinity |
Waveforms/second (continuous) | up to 2500 Waveforms/second |
Operation | Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF |
Analog and Color-Graded Persistence | Variable saturation levels; stores each trace's persistence data in memory |
Persistence Types | Select analog, color, or three-dimensional |
Trace Selection | Activate persistence on all or any combination of traces |
Persistence Aging | Select from 500 ms to infinity |
Sweep Display Modes | All accumulated, or all accumulated with last trace highlighted |
Type | Option LSIB-2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module. |
Transfer Rate | up to 325 MB/s (typical) - Maximum of 4 channels (consult Teledyne LeCroy for >4 channels) |
Output Protocol | PCI Express, Gen 1 (4 lanes utilized for data transfer) |
Control Protocol | TCP/IP |
Command Set | Via Windows Automation, or via LeCroy Remote Command Set |
Processor Memory | 32 GB standard. Up to 192 GB optionally available. |
Operating System | Microsoft Windows® 7 Professional Edition (64-bit) |
Real Time Clock | Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks. |
Zoom Expansion Traces | Display up to 12 Zoom and 12 Math/Zoom traces |
Front Panel and Instrument Status | Store to the internal hard drive, over the network, or to a USB-connected peripheral device. |
Remote Control | Via Windows Automation, or via LeCroy Remote Command Set |
Network Communication Standard | VXI-11 or VICP, LXI Class C (v1.2) Compliant |
GPIB Port | Supports IEEE - 488.2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module. |
LSIB Port (optional) | Supports PCIe Gen1 x4 protocol with LeCroy supplied API. Installs in LabMaster LabMaster MCM-Zi-A Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi-A Acquisition Module. |
Ethernet Port | Supports 10/100/1000BaseT Ethernet interface (RJ45 port) |
USB Ports | LabMaster MCM-Zi -A Master Control Module: minimum 2 total USB 2.0 ports on rear of unit to support Windows compatible devices LabMaster MCM-Zi -A Master Control Module: minimum 3 total USB 2.0 ports on front of unit to support Windows compatible devices |
External Monitor Port | Dual Link DVI compatible to support internal display on MCM-Zi Master Control Module (1280 x 768 pixel resolution) and customer-supplied monitor with up to WQXGA (2560 x 1600 pixel) resolution using extended desktop mode. |
Signal Types | For External Trigger Input. Located on every LabMaster 10-xxZi-A Acquisition Module (front-mounted BNC, 50 Ω). 10-xxZi-A Acquisition Module that is used for Channels 1-4 contains "active" AUX Input. |
Coupling | 50 Ω: DC |
Max. Input Voltage | 5 Vrms |
Signal Types | Select from calibrator, control signals or Off |
Output Signal | 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ) |
Control Signals | Trigger enabled, trigger out, pass/fail status, off |
Connector Type | BNC, located on front of every LabMaster 10-xxZi Acquisition Module. 10-xxZi Acquisition Module that is used for Channels 1-4 contains "active" AUX Output. |
Auto Setup | Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals |
Find Vertical Scale | Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range |
Auto Calibration | Ensures specified DC and timing accuracy is maintained for 1 year minimum. |
Probes | No passive probes supplied |
Probe System | Up to 36 GHz Inputs: 2.92mm interface. Up to 100 GHz Inputs: 1.mm interface 2.92mm interface automatically detects and supports a variety of compatible probes. Use L2.92A-PLINK or L2.92A-PBUS 2.92mm Probe Adapters to connect 50Ω ProLink or ProBus compatible probes to 2.92mm interface. |
Scale Factors | Automatically or manually selected depending on probe used |
Calibration Output | MCM-Zi-A Master Control Module: Fast Edge output, 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled |
Voltage | LabMaster 10-xxZi Acquisition Module: 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II LabMaster MCM-Zi Master Control Module: 100-240 VAC ±10% at 45-66 Hz; Automatic AC Voltage Selection, Installation Category II |
Max. Power Consumption | LabMaster 10-xxZi-A Acquisition Module - 1275 W / 1275 VA. LabMaster MCM-Zi-A Master Control Module - 450 W / 450 VA. Each Module and the CPU has a separate power cord. |
Temperature (Operating) | +5 °C to +40 °C |
Temperature (Non-Operating) | -20 °C to +60 °C |
Humidity (Operating) | 5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C. |
Humidity (Non-Operating) | 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F |
Altitude (Operating) | Up to 10,000 ft. (3048 m) at or below +25 °C |
Altitude (Non-Operating) | Up to 40,000 ft. (12,192 m) |
Random Vibration (Operating) | 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Random Vibration (Non-Operating) | 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Functional Shock | 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total |
Dimensions (HWD) | LabMaster MCM-Zi-A Master Control Module - 10.9"H x 18.2"W x 15.6"D (277 x 462 x 396 mm), LabMaster 10-xxZi-A Acquisition Module - 8.0"H x 18.2"W x 26"D (202 x 462 x 660 mm) |
Weight | LabMaster 10-xxZi-A Acquisition Module -58 lbs. (26.4 kg) LabMaster MCM-Zi-A Master Control Module - 47 lbs. (21.4 kg) |
Shipping Weight | LabMaster 10-xxZi-A Acquisition Module -76 lbs. (34.5 kg) LabMaster MCM-Zi-A Master Control Module - 56 lbs. (25.5 kg) |
Certifications | CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, EN61010-2-030, UL 61010-1 3rd edition, and CSA C22.2 No. 61010-1-12 |
Warranty and Service | 3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services. |